AMR(VP) relay address mark with heating
Number of controlled outputs | 1 |
Current consumption from addressable loop, max., mA | 5 |
Maximum voltage switched by the output contacts: | |
— alternating, max., V | 250 |
— direct, max., V | 30 |
Maximum current switched by the output contacts: | |
— alternating, at 250 V, A | 3 |
— direct, at 30 V, A | 5 |
Test current, mA | 0.8-1.2 |
Voltage in switched circuit, direct or alternating, V | 10-250 |
Max. overall dimensions, mm | 56х47х22 |
Max. weight, kg | 0.2 |
Design lifetime, min, years | 10 |
Status notification sent by the instrument: | |
Status | Notification |
External circuit is in working condition | norm |
External circuit is faulty | No circuit |
Device internal failure | failure |
AMR(VP) relay address mark with heatingя
Number of controlled outputs | 1 |
Current consumption from addressable loop, max., mA | 1.5 |
Maximum voltage switched by the output contacts: | |
— alternating, V | 250 |
— direct, V | 30 |
Maximum current switched by the output contacts: | |
— alternating, at 250 V, A | 0.25 |
— direct, at 12 V, A | 3 |
Test current, mA | 0.8-1.2 |
Voltage in switched circuit, direct or alternating, V | 10-250 |
Max. overall dimensions, mm | 70х47х22 |
Max. weight, kg | 0.2 |
Design lifetime, min, years | 10 |
Status notification sent by the instrument: | |
Status | Notification |
External circuit is in working condition | norm |
External circuit is faulty | No circuit |
Device internal failure | failure |
Number of controlled outputs | 1 |
Current consumption from addressable loop, max., mA | 2 |
Start circuit integrity test current, max., mA | 0.2 |
Current start pulse retention time, min., sec. | 1 |
Current limiting by means of external device in start mode, A | 0.12-0.15 |
Internal capacitor charging time, max., min. | 15 |
Max. overall dimensions, mm | 70х47х22 |
Max. weight, kg | 0.2 |
Design lifetime, min, years | 10 |
Status notification sent by the instrument: | |
Status | Notification |
Everything is in working condition, external circuit in normal condition, capacitor is charged | norm |
Open-circuit failure | No circuit |
Internal reserve capacity is not charged. The capacitor is charged automatically, when power is supplied. Maximum charging time is 15 min. |
failure |