

|
![]() ![]() |
Call time weekdays 8:00-17:00 Ekaterinburg time 04:43 |
Production | The Company | Installation and configuration | Price | Contact us | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
EXPLOSION-PROOF EQUIPMENT
Analog-addressable system “Dialog-Ex”
Non explosion-proof DEVICES
|
Ship date checking
ATTENTION! Beware of imitations! Examples here
The detector unit is designed for sending an alarm signal to the fire alarm loop in case the preset actuation temperature in the controlled environment is exceeded.
The explosion-proof fire heat detector is used at chemical, oil and gas production, oil and gas processing and shipbuilding industry enterprises and in explosion hazardous areas of other production facilities.
Distinctive features and characteristics:
Design:
Setting up of heat detectors to actuation temperature
Our site provides information on fire detectors IP101-07е, IP01-07em, etc.
To order an explosion-proof detector, please call +7 (343) 351-05-07
Our e-mail: market@eridan-zao.ru
![]() |
IP103-2/1-TR detector is entered into Stock item identification guide MTR “Gazprom” OJSC. MTR codes of Gazprom (2016) for the CJSC products |
![]() |
It has a Russian Registry of Shipping type approval certificate |
explosion proofness marking | 1ЕхdIICТ5/Т6 X |
explosion proofness marking for modification with terminal element | 1Ехd[ia]IICТ5/Т6 X |
temperature class of detector’s setting, °С |
75, 90 (classes В, С) A3 - upon request |
supply voltage, V | 6-28 |
maximum switching current, A | 0.1 |
operating conditions: ambient air temperature for the corresponding temperature classes |
Т5 - from - 55°С to +100°С |
Т6 - from - 55°С to +85°С | |
max. overall dimensions, mm | 265x80x190 |
max. weight, kg | 0.9 |
lifetime, min, years | 10 |
warranty period, years | 5 |
TU 4371–001–43082497–98–01
Mounting bracket for IP101-07 and IP103-2/1 series detectors
The bracket is an integral part made of stainless steel for securing explosion-proof fire heat detectors series IP101-07 and IP103-2/1 manufactured by Eridan, CJSC.
![]() |
Bracket | If necessary, please, indicate “with bracket“ in your order |
Cable glands designation:
Appearance | Designation | Definition |
ShT1/2" | pipe union for pipe arrangement with the thread G½" | |
![]() |
ShT3/4" | pipe union for pipe arrangement with the thread G¾" |
![]() |
ShT1" | pipe union for pipe arrangement with the thread G1" (NEW!) |
![]() |
Sh M20 | pipe union for pipe arrangement with the thread М20х1.5 (NEW!) |
![]() |
ShT25 | pipe union for pipe arrangement with the thread М25х1.5 (NEW!) |
![]() |
KVB12 | cable gland for armored cable with max.armor Ø 12 mm |
![]() |
KVB17 | cable gland for armored cable with max.armor Ø 17 mm |
![]() |
KVBU14 | cable gland for armored cable with outer diameter 10-14 mm with double seal along the cable external insulation and cable wrapping with any armor type (NEW!) |
![]() |
KVBU18 | cable gland for armored cable with outer diameter 14-18 mm with double seal along the cable external insulation and cable wrapping with any armor type (NEW!) |
![]() |
KVBU22 | cable gland for armored cable with outer diameter 18-22 mm with double seal along the cable external insulation and cable wrapping with any armor type (NEW!) |
![]() |
KVM15 |
cable gland for installation in metal hose with nominal inside diameter Dn=15 mm
|
![]() |
KVM20 |
cable gland for installation in metal hose with nominal inside diameter Dn=20 mm
|
![]() |
KVM25 | cable gland for installation in metal hose with nominal inside diameter Dn=25 mm |
![]() |
KVO10 | cable gland for surface laying of cable with outer diameter of up to 10 mm (NEW!) |
![]() |
KVO14 | cable gland for surface laying of cable with outer diameter of up to 14 mm (NEW!) |
![]() |
ZG |
terminal plug
|
![]() |
OE** | terminal element (OE)* |
*Terminal element (OE) is not a separate device; it is part of one of the option packages for explosion-proof fire detectors IP103-2/1-TR, IP101-07e and series IP101-07 and it is designed for continuous control of fire alarm loop integrity (it is installed in the last annunciator of the loop).
**as per item 13.15.20 of SP 5.13130.2009:
In case there is no visual control of availability of power supply on the fire detectors connected to the fire alarm radial loop, it is recommended to install a device at the end of the loop that will provide visual control of its condition (for example, a blinking signal device)
A LED on the terminal element indicates that the loop is operational. It operates in flashing mode.
OE electrical specifications:
IP103-2/1-TR
Введите Email | |
РФ | |
Geography of supplies explosion-proof equipment: Moscow, St. Petersburg, Yekaterinburg, Kazan, Perm, Tyumen, Ufa, etc. | ||||
![]() |
|