Call time weekdays 8:00-17:00 Ekaterinburg time 10:00 |
Production | The Company | Installation and configuration | Price | Contact us | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
EXPLOSION-PROOF EQUIPMENT
Analog-addressable system “Dialog-Ex”
Non explosion-proof DEVICES
|
Ship date checking
It is designed for sending an alarm message to the fire alarm loop when the driving element is pulled out.
The explosion-proof call point is used at chemical, oil and gas production, oil and gas processing, shipbuilding facilities and at other plants with explosion hazardous areas.
The call point is manufactured in accordance with GOST R 53325-2012 in two modifications:
class A - one-step activation |
![]() |
class B - activation by performing several actions |
![]() |
ATTENTION! All detectors and call points manufactured by Eridan JSC meet the requirements of effective regulations, rules, norms and other reference documentation. Pursuant to mandatory requirements of GOST R 53325-2012*, after activation and alarm initialization, all current-consuming fire detectors and call points (IP) must switch to standby mode ONLY after being de-energized or upon command from the FACP.
Distinctive features:
Activation of the call point is carried out by means of pulling out the driving element. This activation method is fundamentally different from activation method of the existing comparable call points. Reliability and durability are the IP535-07ea-RS’s design signature.
Design:
Key features:
To order your fire call point please dial: +7 (343) 351-05-07
Or contact us via e-mail: export@eridan.ru
|
The IP535-07ea-RS call point is entered into Stock item identification guide MTR “Gazprom” OJSC. |
|
Certificate of type approval of the Russian Maritime Register of Shipping. |
|
Certificate of type approval of the Russian River Register |
explosion proofness marking | 1Ех db IIC T6 Gb / Ex tb IIIС Т85°C Db |
ingress protection rating | IP66 / IР67 |
supply voltage, V |
8-28
|
max. current consumption, mA | |
- in standby mode (no polling) | 5 |
- in activation mode | 10 |
- in all modes during polling | 20 |
operating conditions, °C | from -60 to +85 |
maximum overall dimensions (without cable glands), mm |
120x135x110
|
maximum weight, kg |
1,0
|
minimum design lifetime, years |
10
|
warranty period, years |
5
|
NEW! Visor for IP535-07e/ea call point and UDP 535-07e START
The visor is a powder-coated steel solid part designed for protection of Eridan-branded IP535-07e series fire call points and IP535-07e START remote start devices from atmospheric precipitation.
Appearance | Designation | Definition |
![]() |
Visor |
If necessary, please, indicate "with Visor" in your order; the canopy is not included in the package by default |
Cable glands designation:
Appearance | Designation | Definition |
ShT1/2" | pipe union for pipe arrangement with the thread G½" | |
![]() |
ShT3/4" | pipe union for pipe arrangement with the thread G¾" |
![]() |
ShT1" | pipe union for pipe arrangement with the thread G1" (NEW!) |
![]() |
Sh M20 | pipe union for pipe arrangement with the thread М20х1.5 (NEW!) |
![]() |
ShT25 | pipe union for pipe arrangement with the thread М25х1.5 (NEW!) |
![]() |
KVB12 | cable gland for armored cable with max.armor Ø 12 mm |
![]() |
KVB17 | cable gland for armored cable with max.armor Ø 17 mm |
![]() |
KVBU14 | cable gland for armored cable with outer diameter 10-14 mm with double seal along the cable external insulation and cable wrapping with any armor type (NEW!) |
![]() |
KVBU18 | cable gland for armored cable with outer diameter 14-18 mm with double seal along the cable external insulation and cable wrapping with any armor type (NEW!) |
![]() |
KVBU22 | cable gland for armored cable with outer diameter 18-22 mm with double seal along the cable external insulation and cable wrapping with any armor type (NEW!) |
![]() |
KVM15 |
cable gland for installation in metal hose with nominal inside diameter Dn=15 mm
|
![]() |
KVM20 |
cable gland for installation in metal hose with nominal inside diameter Dn=20 mm
|
![]() |
KVM25 | cable gland for installation in metal hose with nominal inside diameter Dn=25 mm |
![]() |
KVO10 | cable gland for surface laying of cable with outer diameter of up to 10 mm (NEW!) |
![]() |
KVO14 | cable gland for surface laying of cable with outer diameter of up to 14 mm (NEW!) |
![]() |
ZG |
terminal plug
|
![]() |
OE** | terminal element (OE)* |
*Terminal element (OE) is not an independent device; it is part of one of the package options for IP103-2/1-TR, IP101-07e and IP101-07 series explosion-proof fire detectors and it is designed for continuous control of the alarm loop conditions (it is installed in the last detector of the loop).
** in accordance with clauses 13.15.20, SP 5.13130.2009:
In case there is no visual control of availability of power supply on the fire detectors connected to the fire alarm radial loop, it is recommended to install a device at the end of the loop that will provide visual control of its condition (for example, a blinking signal device)
The LED lamp located on the terminal element indicates good condition of the loop. It works in flashing mode.
OE electrical specifications:
IP535-07-ea-RS
Введите Email | |
РФ | |
Geography of supplies explosion-proof equipment: Moscow, St. Petersburg, Yekaterinburg, Kazan, Perm, Tyumen, Ufa, etc. | ||||
![]() |
|