EXPLOSION-PROOF EQUIPMENT
Analog-addressable system “Dialog-Ex”
Non explosion-proof DEVICES
|
Ship date checking
VS annunciaror is designed for generation of acoustic and light signals in fire and security alarm systems, in joint operation with any fire alarm control units.
The VS annunciator is used at facilities with harsh operating conditions (low temperatures, high dust or moisture content).
Distinctive features:
Key features:
* For operation with consoles that control the annunciator flashing independently (С2000-АСПТ type, version 3.50 or higher), functional jumper LIGHT of the VS-07e-I annunciator must be installed in constant glow mode.
Order the explosion-proof fire annunciator right now: +7 (343) 351-05-07
Our e-mail: market@eridan-zao.ru
We would also like to offer you our acoustic fire annunciator VS-07e-O.
![]() |
VS-07e-O-I Acoustic and Light Fire Annunciator is entered into Stock item identification guide MTR “Gazprom” OJSC. MTR codes of Gazprom (2016) for the CJSC products |
supply voltage, V | 12-24 VDC/100-240 VAC |
maximum current consumption at 12-24 VDC/100-240 VAC, max., A | 0.12 / 0.015 |
minimum sound pressure at a distance of (1.00±0.05) m, dB | 100 |
acoustic signal type is the siren. frequency range of generated acoustic signals, kHz |
1.0 - 4.5 |
light function flashing frequency*, Hz | 0.5 - 2 |
ingress protection rating, IP | 65 |
operating temperature, °С | - 60... +70 |
maximum allowed duration of continuous operation of the annunciator in acoustic signal generation mode, hours | 3 |
max. overall dimensions of the annunciator body without cable glands and bracket, mm | 85x95x140 |
maximum weight of the annunciator, kg | 2 |
lifetime, min, years | 10 |
warranty period, years | 5 |
Cable glands designation:
Appearance | Designation | Definition |
ShT1/2" | pipe union for pipe arrangement with the thread G½" | |
![]() |
ShT3/4" | pipe union for pipe arrangement with the thread G¾" |
![]() |
ShT1" | pipe union for pipe arrangement with the thread G1" (NEW!) |
![]() |
Sh M20 | pipe union for pipe arrangement with the thread М20х1.5 (NEW!) |
![]() |
ShT25 | pipe union for pipe arrangement with the thread М25х1.5 (NEW!) |
![]() |
KVB12 | cable gland for armored cable with max.armor Ø 12 mm |
![]() |
KVB17 | cable gland for armored cable with max.armor Ø 17 mm |
![]() |
KVBU14 | cable gland for armored cable with outer diameter 10-14 mm with double seal along the cable external insulation and cable wrapping with any armor type (NEW!) |
![]() |
KVBU18 | cable gland for armored cable with outer diameter 14-18 mm with double seal along the cable external insulation and cable wrapping with any armor type (NEW!) |
![]() |
KVBU22 | cable gland for armored cable with outer diameter 18-22 mm with double seal along the cable external insulation and cable wrapping with any armor type (NEW!) |
![]() |
KVM15 |
cable gland for installation in metal hose with nominal inside diameter Dn=15 mm
|
![]() |
KVM20 |
cable gland for installation in metal hose with nominal inside diameter Dn=20 mm
|
![]() |
KVO10 | cable gland for surface laying of cable with outer diameter of up to 10 mm (NEW!) |
![]() |
KVO14 | cable gland for surface laying of cable with outer diameter of up to 14 mm (NEW!) |
![]() |
ZG |
terminal plug
|
![]() |
KVP12 |
plastic cable gland for surface cable laying, Ø 6-12 mm (IP67, from -60°С to +75°С) |
VS-07e-O-I